(602) 387-6100
Bright living room with a linear gas fireplace in a stone wall

My gas fireplace remote stopped working. What should I check?

Start with the batteries, and remember there are usually two sets: one in the handheld remote and one in a separate receiver near the fireplace. The receiver is the one people forget, and heat wears its batteries down faster. Put fresh batteries in both, make sure the receiver switch is set to REMOTE, and pair the remote again if your manual says to. If the fireplace still won't come on from the receiver or wall switch, the remote isn't the problem; a receiver replacement in Scottsdale runs $200 to $450.

Scottsdale Chimney · November 19, 2026

Two sets of batteries, not one

The handheld part is a transmitter. It sends a radio signal to a receiver, and the receiver is what actually opens the gas valve. Each has its own batteries. In Skytech's manual for its 3301 remote, the handheld takes two AAA cells and the receiver four AA cells, alkaline recommended, all replaced once a year.

If the remote only works when you stand close to the fireplace, Skytech says to check the batteries.

  • On the hearth or under the firebox, behind the lower grille or control access panel
  • In a wall box next to the fireplace, often with a cover plate that looks like a light switch and a small slide switch
  • On many newer electronic-ignition units, a battery pack or control module inside the lower compartment; your owner's manual shows where

Why summer heat matters in the Valley

Receivers are electronics living next to a burner. Skytech says the inside of its receiver case should stay below 130°F, and that alkaline batteries kept at a steady 115°F can lose up to half their power. They recover part of it as they cool, but months of heating and cooling shorten their life.

That matters here. A receiver under a firebox where the pilot burned all summer runs warmer than the room, and one built into an outdoor fireplace or fire pit base sits through months of Valley sun. Then the first cool nights of late November arrive, someone reaches for the remote, and nothing happens.

Skytech's 3301 also shuts the fireplace off at 130°F inside the case and beeps three times every four seconds. Let it cool, then move or shield the receiver. One that has cooked for years can fail outright and needs replacing.

Pair the remote again and check the slide switch

Every remote sends its own code, and the receiver has to learn it, often again after new batteries go in. Most brands work the same way: set the receiver's slide switch to REMOTE, press the small LEARN or reset button with a paperclip, then press a button on the handheld and listen for beeps.

Skytech's 3301 steps: the receiver won't learn on ON or OFF, only REMOTE. Press and release LEARN, wait for one beep, then press MODE on the remote; several beeps mean it worked. If not, wait one to two minutes and retry. Other brands differ, so follow your own manual.

Skytech also suggests OFF when you're away for a long stretch, so a fireplace shut down for summer may still be on OFF. Range is about 20 feet, and a metal surround can shorten it.

When it isn't the remote at all

Slide the receiver to ON, or use the wall switch. If the fireplace lights, the remote side is at fault. If it doesn't, look deeper.

On a millivolt fireplace with a standing pilot, the pilot's thermopile makes the small current that runs the valve; the remote is just a switch. If the pilot is out, nothing works until you relight it using the plate inside the lower grille. If the pilot burns but ON does nothing, suspect a weak thermopile, the switch wiring, or the gas valve. On electronic ignition, the control module needs its own batteries or adapter, and a dead backup pack looks exactly like a dead remote.

If you smell gas, don't use the remote or any switch. Leave, keep the doors open, and from outside call 911 and Southwest Gas at 877-860-6020, its 24-hour emergency line. On propane, call 911 and your propane supplier.

When to call, and what it costs

Call once you've replaced both sets of batteries, set the switch to REMOTE, tried pairing, and the fireplace still won't run from the receiver's ON setting. Skytech says its receiver wiring should be done by a qualified electrician or gas technician, because wrong connections can damage the valve or module.

Typical Scottsdale prices: an igniter or remote receiver $200 to $450; pilot, thermocouple or thermopile work $150 to $350; a gas valve or control board $400 to $1,200. The diagnostic visit is free, and your exact price is written after the inspection, before any work. Our gas fireplace repair page covers the rest.

FAQ

More answers

Why does my fireplace shut off by itself after a couple of hours?

Some remotes do it on purpose. Skytech's 3301 receiver shuts the fireplace off if it hears nothing from the handheld for two hours. Keep the remote in the room, with good batteries.

My receiver keeps beeping. What does it mean?

On the Skytech 3301, three beeps every four seconds means it is too hot, and a single beep every four seconds means it lost contact with the remote. Other brands use different signals, so check your manual.

Can I replace the receiver myself?

Changing batteries and pairing are owner jobs. Swapping or rewiring the receiver connects to the gas valve or ignition module, and a wiring mistake can damage them, so leave that to a technician.

Saguaro cactus at sunset

Book online

Pick a day. We bring the answers.

Free inspection in a 3-hour window: 8 to 11, 11 to 2, or 2 to 5. We call to confirm before we arrive.

Or call (602) 387-6100

Call (602) 387-6100